BiMBy logo_no equations_color_blue bkg.png

  BiMBy Power Company, LLC

Navigate

Home

Projects

Rosebud Mine, Colstrip, MT - active coal strip mine (for 2 years of mining)

http://bloximages.chicago2.vip.townnews.com/billingsgazette.com/content/tncms/assets/v3/editorial/b/e8/be821313-5a2b-5452-8f85-85dbaede01aa/51c2efbde801f.image.jpg

Rosebud Mine, Colstrip, MT.

 

k/b equivalent to 1 m of dry concrete

Retains 96% of gas pressure after 15 h storage.

Pressure Vessel

V = 3.5 x 107 m3

A = 2.9 x 106 m2

M = 6.1 x 107 t

P  = 4.3 x 105 Pa

Pressurizing Layer

VPL = 3.9 x 107 m3

APL = 3.3 x 106 m2

MPL = 6.9 x 107 t

Whole Device

VT = 7.4 x 107 m3

Amap = 1.6 x 106 m2

MT = 1.3 x 108 t

Assume

ρ = 1.75 t∙m-3

ϕ = 0.3 scalar

Energy Storage Capacity

CAES     9.0 x 105 kW∙h      0.03% of US need

H2           1.4 x 107 kW∙h      0.47% of US need

 

 

Tesla Powerwalls (13.5 kW∙h at $5500 each)

CAES      67k at $366M

H2            1.1M at $5.8B

 

photo: http://billingsgazette.com/news/state-and-regional/montana/rosebud-county-to-reap-million-in-protested-taxes-after-state/article_97128908-6e9b-505a-8019-ae62d0de6910.html, Larry Mayer

This information is provided as an intellectual exercise and is not meant to imply endorsement by any company or community.

 